The smart RAM-1 device is intended for remote monitoring and advanced analysis of power grids. Power grids become Smart with the use of the RAM-1 device, which improves the operating process and the reliability and stability of the electricity transmission and distribution networks. If attached to a gapless surge arrester with a continuous operating voltage above 1 kV the RAM-1 device can measure the resistive component of the leakage current. This innovative method of extracting the resistive component of the leakage current conforms to the standard IEC 60099-5. The measurements can be tracked either via an online or mobile application. One RAM-1 device installed on a surge arrester is sufficient for monitoring a group of three surge arresters installed on one post.
The smart IoT device RAM-1 offers:
• Machine learning;
• Simple installation;
• Communication: 4G, 5G or LoRaWAN;
• Up to 20 years maintenance free and without communication costs.
RAM-1 tracks, analyses and immediately reports the following parameters:
• Excessive environment temperature (fire indication);
• Inclination/tilt or collapse of the pole/pylon/tower;
• Power outage (the presence of voltage);
• Lightning counter and detection of other surge manipulations in network;
• Destruction of arrester;
• Operation of disconnecting device;
• Location of event or fault (provides navigation to the location).
RAM-1 Versions:
• RAM-1 MV A2(A4)* – Voltage up to 110 kV and HV towers;
• RAM-1 HV A2(A4) – Voltage above 110 kV.
* Stainless steel quality A2 or A4.
1. RAM-1 MV* – Voltage up to 110 kV and HV towers
1.1 Monitoring of installation point > 1 kV – RAM-1 MV A2 (A4)
Warnings:
• Collapse or tilt of pole/tower,
• Temperature of surroundings (indication of fire),
• Power outage (presence of voltage),
• Location of event or fault,
• Navigation to location.
Daily reporting:
• Temperature of surroundings,
• Temperature of device.
Required input in to application:
• Picture of installed device,
• Information about place of installation,
• Voltage level,
• Description of installation,
• Installation personnel.
2. RAM-1 HV* – Voltage above 110 kV
2.1 Monitoring of installation point > 110 kV + leakage current monitoring – RAM-1 HV A2 (A4) – Gapless surge arrester
Warnings:
• Collapse or tilt of pole/tower,
• Temperature of surroundings (indication of fire),
• Power outage (presence of voltage),
• Destruction of arrester (instant alert),
• Activation of disconnecting device,
• Exceeded value of resistive component of leakage current,
• Location of event or fault,
• Navigation to location.
Daily reporting:
• State of surge arrester,
• Graphic printout of state of surge arrester,
• Lightning counter,
• Detection of other surge manipulations in network,
• Temperature of surroundings,
• Temperature of device.
Required input in to application:
• Picture of installed device,
• Information about place of installation,
• Voltage level,
• Description of installation,
• Installation personnel.